MARC details
000 -LEADER |
fixed length control field |
02148nam a22002297a 4500 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
UPMIN |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20240930144235.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
240930b |||||||| |||| 00| 0 eng d |
040 ## - CATALOGING SOURCE |
Transcribing agency |
UPMin |
090 ## - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
LG993.5 2020 A7 |
Local cutter number (OCLC) ; Book number/undivided call number, CALL (RLIN) |
R66 |
100 ## - MAIN ENTRY--PERSONAL NAME |
Personal name |
Romuga, Vera Philina M |
9 (RLIN) |
26398 |
245 ## - TITLE STATEMENT |
Title |
Evaluating the thermal performance of the building envelope of condominiums in Davao City / |
Statement of responsibility, etc. |
Vera Philina M. Romuga; Angelo Felix N. Reglado, adviser |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Date of publication, distribution, etc. |
2020 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
274 leaves |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis |
Degree type |
(BS Architecture) |
Name of granting institution |
University of the Philippines Mindanao, |
Year degree granted |
2020 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
This study aims to evaluate and analyze the thermal performance of the building envelopes of mid-rise and high-rise residential condominiums in Davao city. The researcher used the Residential <br/>Envelope Transmittance Value (RETV) formula by the Building and Construction in Singapore to determine the building’s thermal transmittance. Certain parameters were required to measure its RETV such as the window-to-wall ratio, solar heat gain coefficient, u-value of thermal transmittance, and shading coefficient of the fenestration. Solutions were also applied on the condominiums to lessen its initial value of thermal transmittance. According to the requirements of the RETV, the building must not exceed 25 W/m2 for it to be energy-efficient. The researcher studied 10 mid-rise and high-rise residential buildings in Davao city to be able to compare and analyze how different variables affect the RETV of the <br/>building. These variables include the shading devices of the fenestration, the window-to-wall ratio of the building, the materials of the building <br/>envelope, and the orientation of the building. This study proves that consideration of these variables and other different strategies are effective <br/>in having a sustainable design on the building envelopes for future developments. |
658 ## - INDEX TERM--CURRICULUM OBJECTIVE |
Main curriculum objective |
Architectural Design IX: Research Project in Architecture |
Curriculum code |
ARCH191 |
658 ## - INDEX TERM--CURRICULUM OBJECTIVE |
Main curriculum objective |
Architectural design X: Architectural Design Project |
Curriculum code |
ARCH192 |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
Regalado, Angelo Felix N. |
Relator term |
adviser |
9 (RLIN) |
10763 |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
a |
UP |
-- |
Fi |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Library of Congress Classification |
Koha item type |
Thesis |
Suppress in OPAC |
No |