MARC details
000 -LEADER |
fixed length control field |
02314nam a22002653a 4500 |
001 - CONTROL NUMBER |
control field |
UPMIN-00008243667 |
003 - CONTROL NUMBER IDENTIFIER |
control field |
UPMIN |
005 - DATE AND TIME OF LATEST TRANSACTION |
control field |
20230603114934.0 |
008 - FIXED-LENGTH DATA ELEMENTS--GENERAL INFORMATION |
fixed length control field |
230603b |||||||| |||| 00| 0 eng d |
040 ## - CATALOGING SOURCE |
Transcribing agency |
UPMin |
041 ## - LANGUAGE CODE |
Language code of text/sound track or separate title |
eng |
090 #0 - LOCALLY ASSIGNED LC-TYPE CALL NUMBER (OCLC); LOCAL CALL NUMBER (RLIN) |
Classification number (OCLC) (R) ; Classification number, CALL (RLIN) (NR) |
LG993.5 2015 A7 |
Local cutter number (OCLC) ; Book number/undivided call number, CALL (RLIN) |
C677 |
100 ## - MAIN ENTRY--PERSONAL NAME |
Personal name |
Cossid, Julliene Caress V. |
9 (RLIN) |
13041 |
245 ## - TITLE STATEMENT |
Title |
Promoting better local food system : |
Remainder of title |
integrating vertical farming in building design through aquaponics / |
Statement of responsibility, etc. |
Julliene Caress v. Cossid; Jean Marie V. Juanga, adviser |
260 ## - PUBLICATION, DISTRIBUTION, ETC. |
Date of publication, distribution, etc. |
2015 |
300 ## - PHYSICAL DESCRIPTION |
Extent |
136 leaves |
502 ## - DISSERTATION NOTE |
Dissertation note |
Thesis (BS Architecture) -- University of the Philippines Mindanao, 2015 |
520 3# - SUMMARY, ETC. |
Summary, etc. |
The purpose of this study is to promote better local food system by integrating vertical farming in building design through aquaponics. It specifically aims to identify which between mid-rise and high-rise developments will be most efficient with building-integrated agriculture in terms of sufficiency and profitability. To attain the objectives, the most efficient floor area ratios of each building ranging from 7 to 35 stories were obtained. After doing so, a financial analysis for each of which was made in order to determine the return on investment. The computed ROI consequently determine the best among the set of efficient floor area ratios. The results show that for mid-rise buildings, the most efficient floor area ratio of RS:CS:VF is 40:25:10 while for high-rise buildings, the ratio is 45:20:10. Furthermore, results show that in a span of eight years, only high-rise buildings ranging from 32 to 35 stories are projected to have a return of investment of 100% and consequently generate greater income than buildings having 31 floor levels and below. Based on the overall results, it was found that aquaponics is best and most efficient to be integrated in 32 to 35 stories mixed-use high-rise buildings which are found to be the first to generate positive cash flow by year 8. |
658 ## - INDEX TERM--CURRICULUM OBJECTIVE |
Main curriculum objective |
Architectural Design IX: Research Project in Architecture |
Curriculum code |
ARCH191, |
Source of term or code |
BSA, College of Humanities and Social Sciences |
658 ## - INDEX TERM--CURRICULUM OBJECTIVE |
Main curriculum objective |
Architectural Design X: Architectural Design Project |
Curriculum code |
ARCH192, |
Source of term or code |
BSA, College of Humanities and Social Sciences |
700 ## - ADDED ENTRY--PERSONAL NAME |
Personal name |
Juanga, Jean Marie V. |
9 (RLIN) |
602 |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
a |
FI |
905 ## - LOCAL DATA ELEMENT E, LDE (RLIN) |
a |
UP |
942 ## - ADDED ENTRY ELEMENTS (KOHA) |
Source of classification or shelving scheme |
Library of Congress Classification |
Koha item type |
Thesis |